JIS G3462 Alloy Boiler Tubes

Oct 27, 2023

Heat treatment of JIS G3462 STBA23 Alloy boiler and heat exchanger tubes

STBA23

Chemical Composition of JIS G3462 STBA23

Standard:JIS G3462
C P S
STBA23 Less than or equal to 0.15 0.50-1.00 0.30-0.60 Less than or equal to 0.030 Less than or equal to 0.030 1.00-1.50 0.45-0.65

Mechanical Properties of JIS G3462 STBA23




N/mm 2

N/mm 2
Under 10 mm 10 mm or over to and excl. 20 mm 20 mm or over
No. 11 test piece No. 11 test piece No. 11 test piece or No.12 test piece No.4 test piece No.14A test piece
STBA23 410 min. 205 min. 22 min. 25 min. 30 min. 24 min. 21 min.


Under 100 100 or over Under 40 40 or over Under 40 40 or over
Under 2 --- --- +0.4mm +22



0
+0.3 +18



0
0 0
2 or over to and excl. 2.4 +40 --- +20



0
+18



0
0
2.4 or over to or excl. 3.8 +35 +35
0 0
3.8 or over to or excl. 4.6 +33 +33
0 0
4.6 or over +28 +28
0 0


%
--- Within 22.8 of wall thickness --- ---

news-800-600